Packing: New Steel Drum – Jumbo Bag
MOQ: 200 MT
Payment Term: TT Method
Order Now| Test | Method | Unit | Result | Range | |
|---|---|---|---|---|---|
| Dynamic Shear Rheometer (D.S.R) at 76 °C | ASTM D7175 | Kpa | 1.38 | Min 1.0 | |
| Rotational Viscometer (R.V) at 135 °C | ASTM D4402 | Pa.s | 0.61 | Max 3 | |
| Change of Mass | ASTM D2872 | Wt% | 0.02 | – | |
| Flash Point | ASTM D92 | °C | 334 | Min220 | |
| Spot Test | T 102 | – | Neg | Neg | |
| Pressure Aging Vessel (PAV) ASTM D6521 | |||||
| Dynamic Shear Rheometer (D.S.R) at 34 °C | ASTM D7175 | Kpa | 1800 | Max 5000 | |
| Rolling Thin Film Oven Test (RTFO) ASTM D2872 | |||||
| Dynamic Shear Rheometer (D.S.R) at 76 °C | ASTM D7175 | Kpa | 3.12 | Min2.2 | |
| Bending Beam Rheometer (B.B.R) at 0 °C, Stiffness | ASTM D6648 | Mpa | 95.7 | Max 300 | |
| Bending Beam Rheometer (B.B.R) at 0 °C, m-Value | ASTM D6648 | – | 0.32 | Min 0.3 | |